ACCURACY, CLINICAL EFFICIENCY, AND PATIENT PERCEPTION OF DIGITAL VERSUS CONVENTIONAL IMPRESSIONS: AN INTEGRATIVE LITERATURE REVIEW
DOI:
https://doi.org/10.64668/rccss.v2i291102Keywords:
Dental Technology, Dental Impression Technique, Patient Satisfaction, Dimensional Measurement Accuracy, Dental ImplantsAbstract
Objective: To conduct an integrative literature review of the last 10 years to compare trueness, precision, clinical efficiency, and patient perception between digital workflows and conventional techniques. Methodology: An exhaustive bibliographic search was conducted, selecting 50 studies with verified traceability (DOI), limiting the time range to 2015-2025 to ensure technological currency. PubMed, Scopus, and Web of Science were searched (January 2016 - December 2025). Search strategy with MeSH terms included: "Dental Impression Technique", "Intraoral Scanner", "Dimensional Measurement Accuracy", and "Patient Satisfaction". Results: Current evidence indicates that IOS offer comparable or superior accuracy in single and partial restorations. In full-arch rehabilitations, although new algorithms have improved trueness, the conventional technique maintains advantages in complex edentulism situations. Clinical efficiency and patient preference overwhelmingly favor the digital workflow. Conclusion: Digital impression is the preferred standard for most restorative procedures due to its balance of accuracy, efficiency, and comfort, with conventional techniques being reserved for specific cases of high biomechanical complexity.
References
1. Joda T, Brägger U. Patient-centered outcomes comparing digital and conventional implant impression procedures: a randomized crossover trial. Clin Oral Implants Res. 2016 Dec;27(12):e185-e189. Disponible en: DOI: 10.1111/clr.12600
2. Zitzmann NU, Kovaltschuk I, Lenherr P, Dedem P, Joda T. Dental Students' Perceptions of Digital and Conventional Impression Techniques: A Randomized Controlled Trial. J Dent Educ. 2017 Oct;81(10):1227-1232. Disponible en: DOI: 10.21815/JDE.017.081
3. Revilla-León M, Jiang P, Sadeghpour M, Piedra-Cascón W, Zandinejad A, Özcan M, Krishnamurthy VR. Intraoral digital scans-Part 1: Influence of ambient scanning light conditions on the accuracy (trueness and precision) of different intraoral scanners. J Prosthet Dent. 2020 Sep;124(3):372-378. Disponible en: DOI: 10.1016/j.prosdent.2019.06.003
4. Revilla-León M, Jiang P, Sadeghpour M, Piedra-Cascón W, Zandinejad A, Özcan M, Krishnamurthy VR. Intraoral digital scans: Part 2-influence of ambient scanning light conditions on the mesh quality of different intraoral scanners. J Prosthet Dent. 2020 Nov;124(5):575-580.Disponible en: DOI: 10.1016/j.prosdent.2019.06.004
5. Richert R, Goujat A, Venet L, Viguie G, Viennot S, Robinson P, et al. Intraoral Scanner Technologies: A Review to Make a Successful Impression. J Healthc Eng. 2017;2017:8427595. Disponible en: doi: DOI: 10.1155/2017/8427595
6. Revilla-León M, Subramanian SG, Att W, Krishnamurthy VR. Analysis of Different Illuminance of the Room Lighting Condition on the Accuracy (Trueness and Precision) of An Intraoral Scanner. J Prosthodont. 2021 Feb;30(2):157-162. Disponible en: DOI: 10.1111/jopr.13276
7. Waldecker, M., Rues, S., Awounvo Awounvo, JS et al. Precisión in vitro de impresiones digitales y convencionales en el maxilar parcialmente edéntulo. Clin Oral Invest. 2022. 26 , 6491–6502. Disponible en: https://doi.org/10.1007/s00784-022-04598-4
8. Waldecker M, Rues S, Rammelsberg P, Bömicke W. Accuracy of complete-arch intraoral scans based on confocal microscopy versus optical triangulation: A comparative in vitro study. J Prosthet Dent. 2021 Sep;126(3):414-420. Disponible en: DOI: 10.1016/j.prosdent.2020.04.019
9. Waldecker M, Trebing C, Rues S, Behnisch R, Rammelsberg P, Bömicke W. Effects of Training on the Execution of Complete-Arch Scans. Part 1: Scanning Time. Int J Prosthodont. 2021 Jan-Feb;34(1):21-26. Disponible en: DOI: 10.11607/ijp.6903
10. Waldecker M, Rues S, Trebing C, Behnisch R, Rammelsberg P, Bömicke W. Effects of Training on the Execution of Complete-Arch Scans. Part 2: Scanning Accuracy. Int J Prosthodont. 2021 Jan-Feb;34(1):27-36. Disponible en: DOI: 10.11607/ijp.6940
11. de Paris Matos T, Wambier LM, Favoreto MW, Rezende CEE, Reis A, Loguercio AD, Gonzaga CC. Patient-related outcomes of conventional impression making versus intraoral scanning for prosthetic rehabilitation: A systematic review and meta-analysis. J Prosthet Dent. 2023 Jul;130(1):19-27. Disponible en: DOI: 10.1016/j.prosdent.2021.08.022
12. Joda T, Ferrari M, Brägger U. Monolithic implant-supported lithium disilicate (LS2) crowns in a complete digital workflow: A prospective clinical trial with a 2-year follow-up. Clin Implant Dent Relat Res. 2017 Jun;19(3):505-511. doi: 10.1111/cid.12472. Disponible en: DOI: 10.1111/cid.12472
13. Ender A, Zimmermann M, Mehl A. Accuracy of complete- and partial-arch impressions of actual intraoral scanning systems in vitro. Int J Comput Dent. 2019;22(1):11-19. Disponible en: https://pubmed.ncbi.nlm.nih.gov/30848250/
14. Schmidt A, Klussmann L, Wöstmann B, Schlenz MA. Accuracy of Digital and Conventional Full-Arch Impressions in Patients: An Update. J Clin Med. 2020 Mar 4;9(3):688. Disponible en: DOI: 10.3390/jcm9030688
15. Kim RJ, Park JM, Shim JS. Accuracy of 9 intraoral scanners for complete-arch image acquisition: A qualitative and quantitative evaluation. J Prosthet Dent. 2018 Dec;120(6):895-903.e1. Disponible en: DOI: 10.1016/j.prosdent.2018.01.035
16. Renne W, Ludlow M, Fryml J, Schurch Z, Mennito A, Kessler R, Lauer A. Evaluation of the accuracy of 7 digital scanners: An in vitro analysis based on 3-dimensional comparisons. J Prosthet Dent. 2017 Jul;118(1):36-42. Disponible en: DOI: 10.1016/j.prosdent.2016.09.024
17. Park GH, Son K, Lee KB. Feasibility of using an intraoral scanner for a complete-arch digital scan. J Prosthet Dent. 2019 May;121(5):803-810. Disponible en: DOI: 10.1016/j.prosdent.2018.07.014
18. Treesh JC, Liacouras PC, Taft RM, Brooks DI, Raiciulescu S, Ellert DO, Grant GT, Ye L. Complete-arch accuracy of intraoral scanners. J Prosthet Dent. 2018 Sep;120(3):382-388. Disponible en: DOI: 10.1016/j.prosdent.2018.01.005
19. Kuhr F, Schmidt A, Rehmann P, Wöstmann B. A new method for assessing the accuracy of full arch impressions in patients. J Dent. 2016 Dec;55:68-74. Disponible en: DOI: 10.1016/j.jdent.2016.10.002
20. Keul C, Güth JF. Accuracy of full-arch digital impressions: an in vitro and in vivo comparison. Clin Oral Investig. 2020 Feb;24(2):735-745. Disponible en: DOI: 10.1007/s00784-019-02965-2
21. Atieh MA, Ritter AV, Ko CC, Duqum I. Accuracy evaluation of intraoral optical impressions: A clinical study using a reference appliance. J Prosthet Dent. 2017 Sep;118(3):400-405. Disponible en: DOI: 10.1016/j.prosdent.2016.10.022
22. Winkler J, Gkantidis N. Trueness and precision of intraoral scanners in the maxillary dental arch: an in vivo analysis. Sci Rep. 2020 Jan 24;10(1):1172. doi: 10.1038/s41598-020-58075-7. Disponible en: DOI: 10.1038/s41598-020-58075-7
23. Nedelcu R, Olsson P, Nyström I, Rydén J, Thor A. Accuracy and precision of 3 intraoral scanners and accuracy of conventional impressions: A novel in vivo analysis method. J Dent. 2018 Feb;69:110-118. doi: 10.1016/j.jdent.2017. Disponible en: DOI: 10.1016/j.jdent.2017.12.006
24. Iturrate M, Amezua X, Garikano X, Solaberrieta E. Use of measuring gauges for in vivo accuracy analysis of intraoral scanners: a pilot study. J Adv Prosthodont. 2021 Aug;13(4):191-204. Disponible en: DOI: 10.4047/jap.2021.13.4.191
25. Schimmel M, Akino N, Srinivasan M, Wittneben JG, Yilmaz B, Abou-Ayash S. Accuracy of intraoral scanning in completely and partially edentulous maxillary and mandibular jaws: an in vitro analysis. Clin Oral Investig. 2021 Apr;25(4):1839-1847. Disponible en: DOI: 10.1007/s00784-020-03486-z
26. Lee JH, Yun JH, Han JS, Yeo IL, Yoon HI. Repeatability of Intraoral Scanners for Complete Arch Scan of Partially Edentulous Dentitions: An In Vitro Study. J Clin Med. 2019 Aug 8;8(8):1187. Disponible en: DOI: 10.3390/jcm8081187
27. Rutkūnas V, Gedrimienė A, Al-Haj Husain N, Pletkus J, Barauskis D, Jegelevičius D, Özcan M. Effect of additional reference objects on accuracy of five intraoral scanners in partially and completely edentulous jaws: An in vitro study. J Prosthet Dent. 2023 Jul;130(1):111-118. Disponible en: DOI: 10.1016/j.prosdent.2021.09.032
28. Jorquera GJ, Sampaio CS, Bozzalla A, Hirata R, Sánchez JP. Evaluation of trueness and precision of two intraoral scanners and a conventional impression: an in vivo clinical study. Quintessence Int. 2021 Oct 19;52(10):904-910. Disponible en: DOI: 10.3290/j.qi.b1901329
29. Ren S, Morton D, Lin WS. Accuracy of virtual interocclusal records for partially edentulous patients. J Prosthet Dent. 2020 Jun;123(6):860-865. Disponible en: DOI: 10.1016/j.prosdent.2019.08.013
30. Hayama H, Fueki K, Wadachi J, Wakabayashi N. Trueness and precision of digital impressions obtained using an intraoral scanner with different head size in the partially edentulous mandible. J Prosthodont Res. 2018 Jul;62(3):347-352. Disponible en: DOI: 10.1016/j.jpor.2018.01.003
31. Medina-Sotomayor P, Pascual-Moscardo A, Camps A I. Accuracy of 4 digital scanning systems on prepared teeth digitally isolated from a complete dental arch. J Prosthet Dent. 2019 May;121(5):811-820. Disponible en: DOI: 10.1016/j.prosdent.2018.08.020
32. Haddadi Y, Bahrami G, Isidor F. Effect of Software Version on the Accuracy of an Intraoral Scanning Device. Int J Prosthodont. 2018 July/August;31(4):375–376. Disponible en: DOI: 10.11607/ijp.5781
33. Cordaro M, Sailer I, Zarauz C, Liu X, Karasan D. The Accuracy of Full-Arch Intraoral Optical Impressions (IOS): Clinical Pilot Study of the Influence of the Scan Strategy, Operator, and Intraoral Scanner. Int J Prosthodont. 2023 Dec 18;36(6):689-696. Disponible en: DOI: 10.11607/ijp.8113
34. Auškalnis L, Akulauskas M, Jegelevičius D, Simonaitis T, Rutkūnas V. Error propagation from intraoral scanning to additive manufacturing of complete-arch dentate models: An in vitro study. J Dent. 2022 Jun;121:104136. Disponible en: DOI: 10.1016/j.jdent.2022.104136
35. Auskalnis L, Akulauskas M, Jegelevicius D, Rutkunas V. Trueness of Crown Preparation Dies in Dental Models: An In Vitro Assessment of Digital and Analog Workflows. Int J Prosthodont. 2024 Feb 21;37(7):89-98. Disponible en: DOI: 10.11607/ijp.8985
36. Andrade Villalobos M, Bennani V, Aarts JM, Ratnayake J. Accuracy of Intra-Oral Scanners for Full Crown Tooth Preparations with Subgingival Margins: A Systematic Review. Eur J Prosthodont Restor Dent. 2025 Feb 28;33(1):104-112. Disponible en: DOI: 10.1922/EJPRD_2812Matias09
37. Casucci A, Verniani G, Habib R, Ricci NM, Carboncini C, Ferrari M. Accuracy of Four Intra-Oral Scanners in Subgingival Vertical Preparation: An In Vitro 3-Dimensional Comparative Analysis. Materials (Basel). 2023 Oct 4;16(19):6553. Disponible en: DOI: 10.3390/ma16196553
38. Meshni AA, Jain S, Osaysi HNM, Hezam KN, Adlan SSG. The Comparison of Accuracy of Post Space Digital Impressions Made by Three Different Intraoral Scanners: An In Vitro Study. Diagnostics (Basel). 2024 Dec 23;14(24):2893. Disponible en: DOI: 10.3390/diagnóstico14242893
39. Charasseangpaisarn T, Srimakhajon K, Sasiwilasakorn S, Hanvivattanakul K, Sangvichit P, Simapronchai K. Trueness comparison of various intraoral scanners and hybrid workflow for ceramic restoration. J Appl Oral Sci. 2025 Aug 18;33:e20250065. Disponible en: DOI: 10.1590/1678-7757-2025-0065
40. Avgoustis S, Kamposiora P, Papathanasiou I, Papavasiliou G, Nikellis T, Sarafianou A. Accuracy of single implant scans with an intermediate abutment-healing cap system. An in vitro study. J Dent. 2025 Dec;163:106173. Disponible en: DOI: 10.1016/j.jdent.2025.106173
41. Shetty PS, Gangurde AP, Chauhan MR, Jaiswal NV, Salian PR, Singh V. Accuracy of the digital implant impression with splinted and non-splinted intraoral scan bodies: A systematic review. J Indian Prosthodont Soc. 2025 Jan 1;25(1):3-12. Disponible en: DOI: 10.4103/jips.jips_261_24
42. Schott TC, Arsalan R, Weimer K. Students' perspectives on the use of digital versus conventional dental impression techniques in orthodontics. BMC Med Educ. 2019 Mar 12;19(1):81. Disponible en: DOI: 10.1186/s12909-019-1512-3
43. Kraemer-Fernandez P, Spintzyk S, Wahl E, Huettig F, Klink A. Implementation of a Full Digital Workflow by 3D Printing Intraoral Splints Used in Dental Education: An Exploratory Observational Study with Respect to Students' Experiences. Dent J (Basel). 2022 Dec 26;11(1):5. Disponible en: DOI: 10.3390/dj11010005
44. Alhamed FJ, Neiva GF, Bak SY, Karl E, Inglehart MR. Pre-doctoral dental students' computer-aided design/computer-aided manufacturing-related education, knowledge, attitudes and behavior: A national survey. J Dent Educ. 2023 Apr;87(4):562-571. Disponible en: DOI: 10.1002/jdd.13144
45. Wei D, Yi X, Lin Y, Di P. An innovative evaluation method for clinical comparative analysis of occlusal contact regions obtained via intraoral scanning and conventional impression procedures: a clinical trial. Clin Oral Investig. 2024 Sep 24;28(10):543. Disponible en: DOI: 10.1007/s00784-024-05940-8
46. de Oliveira NRC, Pigozzo MN, Sesma N, Laganá DC. Clinical efficiency and patient preference of digital and conventional workflow for single implant crowns using immediate and regular digital impression: A meta-analysis. Clin Oral Implants Res. 2020 Aug;31(8):669-686. Disponible en: DOI: 10.1111/clr.13604
47. Ribeiro CSC, Brandão MTO, Moreira GC, Bitencourt SB, de Carvalho RF, Lemos CAA. Intraoral Scanning Versus Conventional Impression for Implant Prostheses: A Systematic Review. Eur J Prosthodont Restor Dent. 2025 May 28;33(2):206-218. Disponible en: DOI: 10.1922/EJPRD_2811Ribeiro13
48. Park JS, Alshehri YFA, Kruger E, Villata L. Accuracy of digital versus conventional implant impressions in partially dentate patients: A systematic review and meta-analysis. J Dent. 2025 Sep;160:105918. Disponible en: DOI: 10.1016/j.jdent.2025.105918
49. Alfaraj A, Alqudaihi F, Khurshid Z, Qadiri O, Lin WS. Comparative analyses of accuracy between digital and conventional impressions for complete-arch implant-supported fixed dental prostheses-A systematic review and meta-analysis. J Prosthodont. 2025 Jul 14. Disponible en: DOI: 10.1111/jopr.14094
50. Alaghbari SS, Saeed EAM, Zhen L, Al Moaleem MM, Chen H, Gashan BM, Dong S, Niu L, Hu B. Accuracy assessment of digital impressions with varied scanning paths in partially edentulous ridges with mobile abutment teeth: An in vitro comparative study. PLoS One. 2025 Jul 31;20(7):e0327380. Disponible en: DOI: 10.1371/journal.pone.0327380




